Systcold JDC · Versión en español
14/11/2026
Special edition of Systcold JDC: how the Technical Assistant and the IASHAT engine answer, and a real case from this week, replacing R-402B. All figures come from manufacturer catalogs or from calculations validated against published data.
Systcold JDC is a calculation platform for refrigeration installers: it tells you which unit to install and why, using real catalog data. It covers cold room heat load (over 400 products), selection of evaporators, expansion valves and condensing units, copper line sizing and refrigerant changeover. The database holds about 260 manufacturer catalogs: more than 5,000 evaporator models, around 15,500 condensing units and close to 35,000 components.
The Assistant is free and answers with a specific catalog unit: what to install and what to order. It understands short queries without units ("valve 3 kw R404A te -10"), routes them to the specialised layer (evaporators, valves, condensing units), interpolates catalog capacities and shows a "How we read your query" line with what it understood. By default it works at 50 Hz with single-phase units; "60 Hz" or "three-phase" switches to the matching unit version.
| Query | Before | Now |
|---|---|---|
| Condensing unit | 75 s | 0.1–0.2 s |
| Evaporator | 8–15 s | 0.5–0.9 s |
| Expansion valve | 3–6 s | 0.4 s |
IASHAT Engine does not estimate from memory: it calls the same calculation engine used by the web templates, so its results match the website. It relies on recognised methods: a Helmholtz mixture model (the same type as NIST REFPROP) for refrigerants, the AHRI 540 polynomial for compressors, EN 328 conditions and table-based factors for evaporators, and subcooling and pressure-drop corrections for valves.
To retrofit an R-402B (HP81) system, R-448A or R-449A is the general replacement: they keep the COP and discharge temperature with less than half the GWP. Theoretical cycle calculated by Systcold (condensing 40 °C, superheat 5 K, subcooling 2 K, isentropic efficiency 0.70; MT = −10 °C, LT = −30 °C):
| Refrigerant | Capacity MT / LT | Discharge MT / LT | COP MT / LT | Glide | GWP |
|---|---|---|---|---|---|
| R-402B | reference | 73 / 89 °C | 2.77 / 1.65 | 1.7 K | 2416 |
| R-448A | −8 % / −13 % | 73 / 90 °C | 2.79 / 1.66 | 6.2 K | 1387 |
| R-449A | −9 % / −13 % | 72 / 88 °C | 2.79 / 1.66 | 5.8 K | 1397 |
| R-452A | −9 % / −14 % | 61 / 71 °C | 2.67 / 1.56 | 4.2 K | 2140 |
| R-404A | −8 % / −11 % | 61 / 70 °C | 2.60 / 1.50 | 0.6 K | 3922 |
R-402B contains R-22 (HCFC). In the European Union it can no longer be used for recharging, and MARPOL Annex VI has prohibited new installations containing HCFCs on board ships since 2020.
Glide in retrofits: the cycle calculation gives the evaporating and condensing glide of each refrigerant, and the refrigerant changeover template compares it with capacity, COP and discharge temperature. Multi-suction racks: the multi-service project assigns each cold room to HT (+5 °C), MT (−10 °C) or LT (−30 °C) and adds up the load of each suction group to size the condenser; line sizing supports up to 12 nodes and 3 suction groups. Oil return velocity: copper line sizing checks the velocity in every section, node and branch, with the cumulative load of the downstream services.
A result is shown only if it comes from a catalog or from a recognised procedure checked against published data. The pressure-temperature table for R-402B, which has no published table, matches Chemours (≤ 1 %), a supplier data sheet at 72 °F (−0.4 % and −0.1 %) and the Gas Servei glide (0.1 K). The method was first tested on R-404A (0.1–1.7 %).
The Assistant is available on every page of systcoldjdc.com.
▶ Systcold JDC videos and news: YouTube · Facebook · Instagram · Telegram
Sources: Chemours, Freon™ HP80/HP81 · Gas Servei, ficha técnica R402B · Sporlan, tablas de capacidad de válvulas termostáticas · CARB, High-GWP Refrigerants (PCA IPCC AR4) · OMI, MARPOL Anexo VI, regla 12 · Motor de cálculo Systcold JDC
Double opt-in by email. One-click unsubscribe in every issue.