Español

CUBIGEL · Series GPY

Technical answers generated from real manufacturer data loaded in Systcold JDC · free, no registration.

What oil does the Cubigel GPY compressor use?

The CUBIGEL GPY series operates with POE ISO 32 oil according to manufacturer data for 20 models loaded in Systcold JDC. Equivalent oils of the same type and viscosity: Bitzer BSE32, Emkarate RL 32-3MAF, Fuchs Reniso Triton SE 32, Fuchs Reniso Triton SEZ 32, Mobil EAL Arctic 32, Total Planetelf ACD 32. Always confirm with the manufacturer's datasheet before changing brands.

What refrigerants does Cubigel GPY work with and what are its substitutes?

Working gases: R-134a. Substitutes and equivalencies: R-134a→R-513A.

What are the working pressures of Cubigel GPY?

High pressure: 11 bar; low pressure: 0–3 bar (indicative relative working pressure with its refrigerants; high at approximately 45 °C condensation and low in the evaporation range of its application).

What power and electrical supply does Cubigel GPY have?

Power range: 3/8–1/2 HP. Supply: 220-240V 1F 50Hz · 115V 1F 60Hz · 115-127V 1F 60Hz.

What type of compressor is Cubigel GPY and what application is it used for?

Hermetic reciprocating piston compressor, domestic / light commercial application, high / medium / low temperature.

ManufacturerCUBIGEL
SeriesSerie GPY
Type / subtypeHermetic · Piston
ApplicationDomestic / Light Commercial
Operating temperatureHigh / Medium / Low
RefrigerantsR-134a
SubstitutesR-134a→R-513A
High / low pressure (bar)11 / 0–3
Power (HP)3/8–1/2
Power supply220-240V 1F 50Hz · 115V 1F 60Hz · 115-127V 1F 60Hz
Manufacturer oilPOE ISO 32
Equivalent oilsBitzer BSE32, Emkarate RL 32-3MAF, Fuchs Reniso Triton SE 32, Fuchs Reniso Triton SEZ 32, Mobil EAL Arctic 32, Total Planetelf ACD 32
Models in the database20
Find the exact model in the compressor selectorSee the series in the catalogueCalculate the installation

Data from manufacturer catalogues processed by Systcold JDC; oil equivalences and substitutes are indicative: always confirm with the manufacturer's datasheet before working on an installation.