Español

DANFOSS · NUT Series

Technical answers generated from real manufacturer data loaded in Systcold JDC · free, no registration.

What oil does the Danfoss NUT compressor use?

The DANFOSS NUT series operates with POE oil according to manufacturer data for 30 models loaded in Systcold JDC.

What refrigerants does Danfoss NUT work with and what are its substitutes?

Working gases: R-290.

What are the working pressures of Danfoss NUT?

High pressure: 14 bar; low pressure: 0–3 bar (indicative relative working pressure with its refrigerants; high at approximately 45 °C condensation and low in the evaporation range of its application).

What power and electrical supply does Danfoss NUT have?

Power range: 1/8–1/2 HP. Supply: 220-240V 1F 50Hz · 115-127V 1F 60Hz · 220-240V 1F 60Hz.

What type of compressor is Danfoss NUT and what application is it used for?

Hermetic scroll / piston compressor, domestic / light commercial application, medium / low temperature.

ManufacturerDANFOSS
SeriesSerie NUT
Type / subtypeHermetic · Scroll / Piston
ApplicationDomestic / Light Commercial
Operating temperatureMedium / Low
RefrigerantsR-290
Substitutes—
High / low pressure (bar)14 / 0–3
Power (HP)1/8–1/2
Power supply220-240V 1F 50Hz · 115-127V 1F 60Hz · 220-240V 1F 60Hz
Manufacturer oilPOE
Equivalent oils—
Models in the database30
Find the exact model in the compressor selectorSee the series in the catalogueCalculate the installation

Data from manufacturer catalogues processed by Systcold JDC; oil equivalences and substitutes are indicative: always confirm with the manufacturer's datasheet before working on an installation.